AC415V-3500kW RLC Load Bank IP56 Waterproof For Generator Testing
Keyword:
containerized load bank
The Containerized Load Bank is a robust and portable solution for testing, maintaining, and verifying the performance of generators, UPS systems, and electrical distribution networks. Housed in a weatherproof container, it provides safe and reliable load testing under various conditions. Designed for both industrial and commercial applications, the load bank allows precise simulation of electrical loads, ensuring generator stability, efficiency, and compliance with operational standards. With easy transportation, built-in cooling systems, and flexible load configurations, it is ideal for remote sites, power plants, and emergency backup systems.
| Description | ||||
| Model No. | X5000L | |||
| Country of origin | China | |||
Apparent power capacity Active power capacity(PF 1.0) | 5000 kVA 4000 kW | |||
Rated testing voltage Load step(Active power) Load resolution | 400 Vac 100+200+200+500+1000*3KW 100kW | |||
| Reactive power capacoty(PF0.8) | 3000 kVAR | |||
Load step (Reactive power) Load resolution(Reactive power) Frequency | 10+20+20+50+100+100+150*18 KVAR 10kVar 50Hz. | |||
| Phases wires | 3ph 4w | |||
Voltage Tolerance (Short Term Operation) | +5% | |||
| Load Element Tolerance | ≤+2.5% | |||
| Insulation Test | 600 Vac | |||
| Load Connections | Copper busbars | |||
Protection
Control voltage | Thermal emergency cut out | |||
| Air flow switch | ||||
| Fan overload protection | ||||
| Emergency stop | ||||
| 3ph 400VAC | 50/60HZ. | |||
| Airflow volume(Approx. CMM) | 26000 CM/H *8 | |||
| Airflow direction | Vertical upwards air forced cooling | |||
Fans Nos. Load switching contactor type | 12 pcs . (4kW each) 3 pole AC contactors | |||
Rated maximum ambient temp. operation | +60°C / +140°F | |||
Rated minimum operation | ambient | temp. | -20°C / -4°F | |
| Altitude rating | ≤2000 [m.a.s.l] or customized | |||
| Control chamber IP rating | IP 54 outdoor | |||
| Enclosure material | Containerised carbon steel with marine grade painting. | |||
| Portabality | Standard ISO lifting points | |||
| Enclosure dimentions | ||||
| Length(mm) | 9500 | |||
| Width(mm) | 2438 | |||
| Height(mm) | 2800 | |||
| Weight of load bank | 20000 Maximum | |||







Understanding components of load banks
Load banks are assembled with various quantities of components . for example , Load element- reactors/resistors , PLC ,AC/DC contactors, fuses, circuit breakers, temperatures sensors, relays,switchingmode power supply ,voltage/current transformers ,limit switches, terminal connectors, LEDs, push buttons/toggles, cables, busbars etc. Pics for reference:

CONSULT
NOW
If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in time, or please call us directly.