New Arrival SILV-500kw Resisitive Load Bank For Generator Testing --Manufacturer Rata

Keyword:

Product Introduction

Engineered with a 415Vac rated testing voltage, 1kW load step resolution, and a flexible load step configuration, the SILV500-L provides ultra-precise control over load testing scenarios, while its continuous operation capability and rugged construction (2mm thick steel IP54 enclosure, 400A waterproof quick connectors) ensure uncompromising performance in extreme ambient conditions from -20°C (-4°F) to +50°C (122°F) and at altitudes up to 2000m.a.s.l.

 

Equipped with HMI touch screen manual control, PC software remote operation, and Modbus TCP communication, it enables automated, real-time testing with seamless data integration, optimizing workflows for power system manufacturers, maintenance teams, and industrial facilities worldwide. Boasting thermal emergency cut-out, fan overload protection, and emergency stop features, this load bank prioritizes operational safety, while its castor-mounted portability and horizontal forced air cooling (70m³/h per kW airflow) enhance usability and durability for both indoor and outdoor applications. Certified for global compliance, the SILV500-L merges cutting-edge engineering with practical design, meeting the stringent demands of the international electrical testing market and supporting sustainable power infrastructure development.

Product Specifications

 

Model No.

 

SILV500-L

Country of origin

China

Max capacity

500kW

Rated testing voltage

415Vac

Frequency

50/60Hz.

Phases

3

Wires(Star connection)

4

Load step resolution

1kW

Load step (kW)

1 +2+2+5 +10+10+20+50+ 100+100+200

Voltage Tolerance (Short Term Operation)

5%

Load Element Tolerance

± 3%

Insulation Test

600Vac

Load Connections

400A waterproof quick connector

Protection

Thermal emergency cut out

Air flow switch

Fan overload protection

Emergency stop

 Control voltage

415Vac  / 3 phases 5wires

Cooling method

Air forced cooling

Airflow volume(Approx. CMM)

Each kW 70m³/h

Airflow direction

Horizontal

Load switching contactor type

3 pole AC contactors

Rated maximum ambient temp. operation

+50°C / +122°F

Rated minimum ambient temp. operation

-20°C / -4°F

Altitude rating

<2000m [m.a.s.l.]

Control chamber IP rating

IP 54 (Outdoor using)

Portabality

Castor*4

Enclosure dimentions

Length(mm)

1155

Depth(mm)

1205

Height(mm)

1120

Weight(KG)

800

Load bank control system

Manual control Remote control

HMI touch screen+ digital meter PC Software

Communication

Modbus TCP.

Test voltage(3 phases)

Power derating with lower voltage

applied.

415V

500 kW

400V

464.5 kW

Description