18kW Rack-mounted Load Bank For Data Center

Rata's 18kW Rack-mounted Load Bank has a reliability rate unrivaled on the market, which is specifically designed to support airflow testing and cooling system verification within the facility.

Keyword:

DC electronic load bank

Product Introduction

DC electronic load bank is a high-performance testing equipment designed for simulating real load conditions of DC power sources such as batteries, power supplies, and photovoltaic systems. It provides precise constant current, constant voltage, constant resistance, and constant power modes, ensuring accurate evaluation of power performance and reliability. The system supports programmable control, multiple protection functions, and real-time monitoring of voltage, current, power, and temperature. Widely used in R&D laboratories, manufacturing quality inspection, and industrial production lines, the DC electronic load bank helps engineers optimize power system efficiency and safety. With modular design and flexible configuration, it can be customized according to different voltage and current requirements. Its fast response and high stability make it suitable for aging tests, discharge tests, and long-term endurance testing of DC power equipment.

 

Rata's 18kW Rack-mounted Load Bank has a reliability rate unrivaled on the market, which is specifically designed to support airflow testing and cooling system verification within the facility.

Applications:

 

Data centers/Generators/Power systems/New energy sources/Laboratory testing.
Key Features
18kW Rack-mounted Load Bank For Data Center 7
Adjustable Airflow Levels
30%, 60%, 90%, and 100%, with a control accuracy of within ±2%.
18kW Rack-mounted Load Bank For Data Center 8
High-Performance Cooling Fans
 
Customized DC 26V fans, with 10 units providing a total airflow of 5,570 m³/h.
18kW Rack-mounted Load Bank For Data Center 9
Advanced Protection
Equipped with an 80°C over-temperature alarm and automatic section cut-off at 90°C to ensure safe and reliable operation.
0 (2) 拷贝 (2)
Switching System
Load step control realized through Schneider circuit breakers, ensuring durability and precise operation.
ProductSpecifications

Model No.

RTLB18-RM

Protection

Thermal emergency cut out; 80℃ red light alert; 90℃ trip off

Country of origin

China

Thermal protection

Contactor

Max capacity

18kW

Cooling method

Air forced cooling

Rated testing voltage

400Vac

Fans Nos.

10pcs  26Vdc

Frequency

50/60Hz.

Airflow volume

5508≥m³/ h

Phases

3

Airflow level

0, 30% , 60% , 90% , 100% ( Airflow tolerance: ±2% )

Load step

L1: 1+2+3kW; L2: 1+2+3kW; L3: 1+2+3kW

Airflow direction

Front air inlet , rear air outlet

Resistors type

Finned heating resistive tube

Rated maximum ambient temp. operation

+50°C / +122°F

Voltage Tolerance (Short Term Operation)

+5%

Rated minimum ambient temp. operation

-20°C / -4°F

Load Element Tolerance

± 3%

Altitude rating

<500m [m.a.s.l.]

Insulation Test

500Vac

Control chamber IP rating

IP 23

Load Connections

TYP325 ( 32A Five-pin plug connector)

Portability

5 Foldable handle clips

 

CONSULT

NOW