10kW

Rack-mounted AC dummy load equipment can fully simulate the power usage, heat dissipation, and other airflow changes of servers. By using rack-mounted load bankes for integrated testing, it ensures the effective operation of the data center's power distribution system (including the UPS system)

Keyword:

Rack-mounted AC dummy load equipment can fully simulate the power usage, heat dissipation, and other airflow changes of servers. By using rack-mounted load bankes for integrated testing, it ensures the effective operation of the data center's power distribution system (including the UPS system), air conditioning fresh air system, lightning grounding system, monitoring system, integrated environment of the machine room, IT environment of the cabinets, and various systems of the machine room decoration project, as well as verifying that they meet design and operational requirements. Rack-mounted AC dummy loads are widely used for simulating loads in data centers and switch rooms. Rack-mounted AC dummy loads can also be used as loads in other industries.

Product Series

Power (kW)

Voltage (V)

Frequency (Hz)

Chassis Height

Load Step

Function

3

220/240

50/60

3U

0.5kW

Fan speed regulation, dual power supply switching

3.5

220/240

50/60

3U

0.5kW

Fan speed regulation, dual power supply switching

4

220/240

50/60

4U

0.5kW

Fan speed regulation, dual power supply switching

4.5

220/240

50/60

4U

0.5kW

Fan speed regulation, dual power supply switching

5

220/240

50/60

6U

0.5kW

Fan speed regulation, dual power supply switching

6

220/240

50/60

6U

0.5kW

Fan speed regulation, dual power supply switching

7

220/240

50/60

6U

0.5kW

Fan speed regulation, dual power supply switching

8

220/240

50/60

8U

0.5kW

Fan speed regulation, dual power supply switching

9

220/240

50/60

8U

0.5kW

Fan speed regulation, dual power supply switching

12

220/240

50/60

10U

0.5kW

Fan speed regulation, dual power supply switching

Product Example

The 7kW rack-mounted load unit can fully simulate the power consumption, heat dissipation, and other airflow variations of servers. By using a rack-mounted load unit for integrated testing, it ensures the effective operation of the power supply and distribution system (including UPS systems), fresh air conditioning systems, lightning protection grounding systems, monitoring systems, comprehensive environment of the computer room, IT environment of the cabinets, and the renovation project of the computer room, thereby validating design and operational requirements. The 7kW rack-mounted AC virtual load is widely used in data centers and power distribution rooms. Rack-mounted AC virtual loads can also be used as loads in other industries.

Parameter table

Product Name

7kW Rack-mounted load bank

Product Specifications

RT7kW/AC230V

Rated Power

7kW

Rated Voltage

AC230V

Maximum Load Power

1kW

Step Distribution

1kW, 2kW×3

Loading Accuracy

±2%

Connection Method

Three input terminals, independent power input terminal

Control Power

AC220V/50Hz

Insulation Class

F

Operating Mode

Continuous operation

Cooling Method

Forced air cooling, front intake, rear exhaust

Control Method

Manual small circuit breaker for load switching

Color

Customizable

Ambient Temperature

-20℃ to 50℃

Humidity

≤100%

Altitude

≤2500m

Atmospheric Pressure

86 to 106kPa

Prev: 8kW racks

Next: 12kW