Rata Hydro-100L AC liquid-cooled resistive load bank
Keyword:
Product Introduction
Our liquid-cooled load bank successfully passed the factory acceptance test for our Japanese customer. This load bank can be controlled via an HMI panel, connected via RJ45 network cable using our software, or via Wi-Fi. It includes functions for inlet and outlet flow rate, temperature difference (ΔT), pressure difference, and leak detection. Our testing methods include two modes: a power loading mode, which detects temperature rise under fixed flow and pressure conditions.
The second mode allows setting a temperature rise value, enabling the load bank to automatically apply power based on temperature. Furthermore, customers can set upper and lower limits for inlet/outlet temperature/flow/pressure, alarm values, and adjust parameters according to the specific heat capacity of different coolants. More importantly, our liquid-cooled load cells can be paralleled with air-cooled load banks. Our comprehensive liquid-cooled load bank solution can meet the testing needs of most data centers, offering versatility and significantly reducing customer manpower and time costs.
Enclosure drawings
100kw for ref. (mm)
![]() |
Key details
![]() | ![]()
| ![]() |
Main Parameters
| Model No. | RTHydro-100L |
| Country of origin | China |
| Rated power | 100kW(101.5kW Max) |
| Rated testing voltage | 400Vac |
| Control voltage (Auxiliary power supply) | 230Vac 1Ph, from external |
| Frequency | 50Hz/60Hz |
| Power Factor | 1.0 |
| Phases & Wires | 3P4W (A B C N) |
| Load step resolution | 1kW |
| Active load steps (kW) | 1kW+2kw*2+5kw+10kw*2+20kw+50kw |
| Load accuracy | ±3% |
| Power load response time | <0.1 sec |
| Estimated Width*Depth*Height(mm) | 800mm*1000mm*1380mm (pipe excluded) |
| Estimated Weight (kg) | 300kgs (empty tank) |
| Cooling method | Coolant |
| Coolant direction | Down-in, Top-out |
| Functions | To simulate flow rate, temperature difference ( ΔT), pressure difference, and leakage detection equivalent, WIFI control |
| Operation mode | 1. Temperature ΔT control mode2. Power control mode |
| Enclosure Protection IP rating | IP 44 indoor |
| Enclosure material | Cold rolled steel plate with painting. |
| Enclosure color | RAL 7012 Industrial Grey |
| Tank material | Stainless steel 304 |
| Tank quantity | 1 |
| Tank withstand pressure | 1Mpa |
| Portability | Forklift holes and heavy duty casters with brakes, hooks |
| Flow range | 30.1 L/min - 227.3 L/min |
| Safety relief valve | 0.45.0 Mpa |
| Operating pressure | Max. 0.48 MPa |
| Rated maximum/minimum ambient temp. operation | 5°C ~ 40°C |
| Outlet temperature | 50°C max |
| Delta T. | 1. 18°C (±0.5°C)at load control mode (natural water testing environment) 2. Adjustable at Delta T control mode |